125A 3-Phase TYPE 3 Distro
IP44
OUTPUTS
12 x 16A 1-Phase
12 x 32A 1-Phase
2 x 32A 3-Phase
1 x 63A 3-Phase
INCOMING:
125A 3-Phase 230/400V 5-Pole Inlet
INLET PROTECTION:
None Dedicated
OUTGOING:
– Circuit 1 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 2 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 3 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 4 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 5 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 6 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 7 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 8 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 9 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 10 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 11 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 12 – 16A 1-Phase 230V socket
Protection: 16A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 13 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 14 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 15 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 16 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 17 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 18 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole RCBO (C-Curve) with 30mA Earth Leakage protection.
– Circuit 19 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole MCB (C-Curve). PLEASE NOTE NO RCD PROTECTION ON THIS CIRCUIT.
– Circuit 20 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole MCB (C-Curve). PLEASE NOTE NO RCD PROTECTION ON THIS CIRCUIT.
– Circuit 21 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole MCB (C-Curve). PLEASE NOTE NO RCD PROTECTION ON THIS CIRCUIT.
– Circuit 22 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole MCB (C-Curve). PLEASE NOTE NO RCD PROTECTION ON THIS CIRCUIT.
– Circuit 23 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole MCB (C-Curve). PLEASE NOTE NO RCD PROTECTION ON THIS CIRCUIT.
– Circuit 24 – 32A 1-Phase 230V socket
Protection: 32A 2-Pole MCB (C-Curve). PLEASE NOTE NO RCD PROTECTION ON THIS CIRCUIT.
– Circuit 25 – 32A 3-Phase 230/400V socket
Protection: 32A 3-Pole MCB (C-Curve).
– Circuit 26 – 32A 3-Phase 230/400V socket
Protection: 32A 3-Pole MCB (C-Curve).
– Circuit 27 – 63A 3-Phase 230/400V socket
Protection: 63A 3-Pole MCB (C-Curve).
Related products